The new ELEMENTRAC ONH-ps is a powerful and robust elemental analyzer for the simultaneous determination of oxygen, nitrogen and hydrogen concentrations in inorganic samples such as steel, iron, copper or ceramics. The highly sensitive NDIR cells without moving parts and the thermal conductivity detector for nitrogen measurement reliably detect element concentrations from the low ppm range to the high percentage range.
Thanks to the novel sample lock with pulsed chamber purging and vertical fall channel, user-friendly and convenient analysis of rod-shaped, granular or powdery samples with a weighed portion of up to 2 grams is easily possible. The ELEMENTRAC ONH-ps elemental analyzer meets or exceeds the requirements of all common international standards, such as ASTM E 1019 or DIN EN 3976.
aço, cobre, ligas , metais refratários, ferro fundido , cerâmica , carbonetos, ferroligas, ferro, metais, alumínio, silício , ...
Etapa 1: registrando a amostra no software ELEMENTS
A identificação da amostra é registrada no software e o peso é transferido automaticamente (consulte a etapa 2).
Etapa 2: Pesagem e introdução da amostra na porta de amostra
The ELEMENTRAC ONH-ps analyzes volumes from a few mg up to 2 grams safely and precisely. Rod-shaped or granular samples can be applied directly. For the elemental analysis of powders, a capsule is recommended which does not have to be sealed.
Etapa 3: Análise
O cadinho de grafite vazio é então colocado no eletrodo inferior e a análise é iniciada através do software ELEMENTS. O software controla todas as etapas de análise subsequentes.
Etapa 4: saída e exportação de dados
120 a 180 segundos após o início da análise, as concentrações medidas estão disponíveis para exportação como um relatório ou via LIMS.
Common O/N/H analysis for inert gas fusion analyzers mean that a thermal conductivity cell is used for both hydrogen as well as for nitrogen analysis. This means that two independent measurements have to be performed when determination of nitrogen and hydrogen is required. The ELEMENTRAC ONH-ps utilizes a new designed water IR cell without moving parts which allows a reliable measurement of hydrogen as water even in the lower ppm concentration range. This allows the simultaneous measurement of oxygen, nitrogen and hydrogen in one sample.
Element | Measured as | Detector | ||||
Oxygen | CO2 | IR | ||||
Nitrogen | N2 | TCD | ||||
Hydrogen (Common technique) | H2 | TCD | ||||
Hydrogen(new technique) | H2O | IR |
The ELEMENTRAC ONH-ps is a multi-element analyser for the parallel determination of oxygen, nitrogen and hydrogen (ONH). While oxygen is detected as CO2 and hydrogen as H2O in infrared measuring cells, nitrogen is determined in elemental form using a thermal conductivity cell. The ELEMENTRAC ONH-ps uses helium or, alternatively, argon as the carrier gas.
The ELEMENTRAC ONH-ps uses our newly developed infrared measuring cells without moving parts. These measuring cells are characterised by a very good signal-to-noise ratio and high stability.
The ELEMENTRAC ONH-ps elemental analyzer is available as a single-element analyzer for hydrogen only, or in a multi-element configuration for measuring ONH. Whereas oxygen and hydrogen are determined as CO2 and H2O in up to three infrared cells, nitrogen is detected in its elemental form in a thermal conductivity cell.
Os produtos químicos e filtros necessários para a operação do ELEMENTRAC ON-p 2 estão convenientemente dispostos no painel frontal e podem ser escondidos atrás de uma porta removível durante a operação de rotina. Esse arranjo reduz significativamente o tempo necessário para manutenção e aumenta a facilidade de uso. Além disso, detalhes inovadores melhoram consideravelmente a reprodutibilidade das medições.
Inovador porta amostra & câmera com dispensa pulsante
The new sample port of the ONH-ps elemental analyzer ensures comfortable operation and reproducible measured values. Differently shaped materials like solid pieces, granules or powder in capsules can be applied up to a weight of 2000 mg, and are quickly freed from the surrounding atmosphere with the help of pulsed carrier gas flushing in the sample port. Then they drop vertically into the preheated graphite crucible for analysis.
Poderoso Catalisador
During fusion of the sample CO is formed, whereas hydrogen and nitrogen are released in elemental form. The powerful catalyst furnace oxidizes CO to CO2 and hydrogen to water, which are subsequently measured in the IR cells. The high temperature catalyst furnace with copper oxide filling guarantees the complete oxidation of CO to CO2 and of course of H2 to gaseous H2O.
Gerenciamento de fechamento do gás
The ELEMENTRAC ONH-ps elemental analyzer series uses a closed gas system in overpressure. This ensures that always 100% of the released sample gas is fed to the detectors which guarantees low detection limits and good reproducibility.
Limpador automático
Ao derreter a amostra em um cadinho de grafite em temperaturas de até 3000 ° C, depósitos são gerados no eletrodo superior e na câmara do forno que podem afetar a reprodutibilidade das medições de ONH de forma negativa. O novo Limpador Automático opcional remove de forma confiável esses depósitos, permitindo uma análise precisa do gás, mesmo para um alto rendimento de amostra. Além disso, uma calibração de gás eficiente e um forno de limpeza de gás para uma pré-limpeza completa do gás de arraste estão disponíveis.
Todos os analisadores ELTRA integram-se perfeitamente à plataforma IoT da Verder Scientific, proporcionando funcionalidades aprimoradas, conectividade sem emendas e benefícios adicionais:
Experimente hoje o poder da plataforma IoT da Verder Scientific e desbloqueie todo o potencial dos seus analisadores ELTRA!
The ELEMENTRAC ONH-ps uses a measuring principle with a wide operating range. To analyse the sample, it is weighed and placed in the sample lock. Flushing with carrier gas ensures that no atmosphere (e.g. nitrogen and oxygen) enters the analysis chamber.
The graphite crucible is then annealed in the pulse furnace to reduce any contamination, such as residual hydrogen. After a stabilisation phase, the sample falls into the graphite crucible and is melted. Elemental nitrogen, hydrogen and carbon monoxide are released from the sample melt into the carrier gas stream. The carbon monoxide comes from the reaction of the carbon in the graphite crucible with the oxygen in the sample. The carrier gas (helium) and the sample gas pass through a dust filter before entering a copper oxide catalyst, where CO is converted to CO2 and elemental hydrogen to H2O.
The resulting CO2 and H2O are then detected in the infrared cells. CO2 and H2O are chemically removed and the nitrogen content is measured in the heat conduction cell.
Optionally, inexpensive argon can be used instead of helium as the carrier gas for determining oxygen and nitrogen.
Elementos | hidrogênio, nitrogênio, oxigênio |
Tipo de amostra | inorgânico |
Alinhamento do forno | vertical |
Suporte de amostra | Cadinho de grafite |
Campo de aplicação | automotive, aviation, metal production, metallurgy, quality control, research |
Tipo de forno | Forno de impulso (máx. 8,5 KW*), para temperaturas acima de 3.000°C |
Princípio de medição | infrared absorption for oxygen and hydrogen, thermal conductivity for nitrogen |
tempo de análise típico | 120 - 180 s |
Produtos químicos necessários | hidróxido de sódio, perclorato de magnésio, Óxido de cobre |
Gases requeridos | ar comprimido, hélio 99,995% puro, argônio 99,995% puro (se necessário), todos os gases com (2 - 4 bar / 30 - 60 psi) |
alimentação elétrica | 3~ 400 V, 50/60 Hz, max. 8,500 W |
Dimensões (L x A x P) | 56 x 78 x 64 cm |
Peso | ~ 165 kg |
acessórios necessários | PC, monitor, balança (resolução 0.0001g) |
Acessórios opcionais | autocleaner, autoloader, external chiller, purificação do gás de transporte |
- | * limitado a 6,8 kW em aplicações |
Sujeito a alterações técnicas e erros