The new ELEMENTRAC ONH-ps is a powerful and robust elemental analyzer for the simultaneous determination of oxygen, nitrogen and hydrogen concentrations in inorganic samples such as steel, iron, copper or ceramics. The highly sensitive NDIR cells without moving parts and the thermal conductivity detector for nitrogen measurement reliably detect element concentrations from the low ppm range to the high percentage range.
Thanks to the novel sample lock with pulsed chamber purging and vertical fall channel, user-friendly and convenient analysis of rod-shaped, granular or powdery samples with a weighed portion of up to 2 grams is easily possible. The ELEMENTRAC ONH-ps elemental analyzer meets or exceeds the requirements of all common international standards, such as ASTM E 1019 or DIN EN 3976.
acél, réz, ötvözetek, hőálló fémek, öntöttvas, kerámia, karbidok, ferro-ötvözetek, vas, fémek, alumínum, szilícium, ...
1. lépés: Minta bejelentése az ELEMENTS szoftverbe
A minta és azonosítószáma (ID) bejelentkezik a szoftverbe, súlya automatikusan beolvasódik (lásd 2. lépést).
2. lépés: Minta súlya bemérése és bevitele a mintabevezető zsilipbe.
The ELEMENTRAC ONH-ps analyzes volumes from a few mg up to 2 grams safely and precisely. Rod-shaped or granular samples can be applied directly. For the elemental analysis of powders, a capsule is recommended which does not have to be sealed.
3. lépés: Analízis
Üres grafittégely felhelyezése az alsó elektródára, majd az elemanalízis megindítása az ELEMENTS szoftverrel. Az összes további műveletet a szoftver vezérli.
4. lépés: Mért adatok megjelenítése és exportálása
Az analízis megkezdése után 120-180 s elteltével a kijelzőn már megjelennek a mért koncentrációadatok, melyek átírhatók jegyzőkönyvbe vagy exportálhatók LIMS rendszerbe.
Common O/N/H analysis for inert gas fusion analyzers mean that a thermal conductivity cell is used for both hydrogen as well as for nitrogen analysis. This means that two independent measurements have to be performed when determination of nitrogen and hydrogen is required. The ELEMENTRAC ONH-ps utilizes a new designed water IR cell without moving parts which allows a reliable measurement of hydrogen as water even in the lower ppm concentration range. This allows the simultaneous measurement of oxygen, nitrogen and hydrogen in one sample.
Element | Measured as | Detector | ||||
Oxygen | CO2 | IR | ||||
Nitrogen | N2 | TCD | ||||
Hydrogen (Common technique) | H2 | TCD | ||||
Hydrogen(new technique) | H2O | IR |
The ELEMENTRAC ONH-ps is a multi-element analyser for the parallel determination of oxygen, nitrogen and hydrogen (ONH). While oxygen is detected as CO2 and hydrogen as H2O in infrared measuring cells, nitrogen is determined in elemental form using a thermal conductivity cell. The ELEMENTRAC ONH-ps uses helium or, alternatively, argon as the carrier gas.
The ELEMENTRAC ONH-ps uses our newly developed infrared measuring cells without moving parts. These measuring cells are characterised by a very good signal-to-noise ratio and high stability.
The ELEMENTRAC ONH-ps elemental analyzer is available as a single-element analyzer for hydrogen only, or in a multi-element configuration for measuring ONH. Whereas oxygen and hydrogen are determined as CO2 and H2O in up to three infrared cells, nitrogen is detected in its elemental form in a thermal conductivity cell.
Az elemanalizátor működéséhez szükséges vegyszerek és szűrők könnyen hozzáférhető módon az előlapon vannak elhelyezve, rutin alkalmazások esetén ezek levehető ajtó mögé rejthetők. Ez az elrendezés lényegesen csökkenti a karbantartás időigényét és növeli a használat kényelmét. Egyéb innovatív részletmegoldások még tovább növelik a mérések reprodukálhatóságát
Innovatív mintazsilip és pulzált kamraöblítés
The new sample port of the ONH-ps elemental analyzer ensures comfortable operation and reproducible measured values. Differently shaped materials like solid pieces, granules or powder in capsules can be applied up to a weight of 2000 mg, and are quickly freed from the surrounding atmosphere with the help of pulsed carrier gas flushing in the sample port. Then they drop vertically into the preheated graphite crucible for analysis.
Hatékony katalizátor
During fusion of the sample CO is formed, whereas hydrogen and nitrogen are released in elemental form. The powerful catalyst furnace oxidizes CO to CO2 and hydrogen to water, which are subsequently measured in the IR cells. The high temperature catalyst furnace with copper oxide filling guarantees the complete oxidation of CO to CO2 and of course of H2 to gaseous H2O.
Zárt gázrendszer
The ELEMENTRAC ONH-ps elemental analyzer series uses a closed gas system in overpressure. This ensures that always 100% of the released sample gas is fed to the detectors which guarantees low detection limits and good reproducibility.
"Autocleaner"
Az akár 3000 °C hőmérsékletű grafittégelyben lévő minta megolvadása a felső elektródán és a kemencekamrában lerakódásokat idézhet elő, melyek leronthatják a ONH mérések reprodukálhatóságát.
Az új opcionális "Autocleaner" megbízhatóan eltávolítja ezeket, és így lehetővé teszi a pontos elemanalízist még nagy mennyiségű minta esetén is. Ezen kívül még hatékony gázkalibrálás és a vivőgáz előtisztítását szolgáló tisztító kemence is rendelkezésre áll.
All ELTRA analyzers seamlessly integrate with the Verder Scientific IoT platform, providing enhanced functionality, seamless connectivity, and additional benefits:
Experience the power of the Verder Scientific IoT platform today and unlock the full potential of your ELTRA analyzers!
The ELEMENTRAC ONH-ps uses a measuring principle with a wide operating range. To analyse the sample, it is weighed and placed in the sample lock. Flushing with carrier gas ensures that no atmosphere (e.g. nitrogen and oxygen) enters the analysis chamber.
The graphite crucible is then annealed in the pulse furnace to reduce any contamination, such as residual hydrogen. After a stabilisation phase, the sample falls into the graphite crucible and is melted. Elemental nitrogen, hydrogen and carbon monoxide are released from the sample melt into the carrier gas stream. The carbon monoxide comes from the reaction of the carbon in the graphite crucible with the oxygen in the sample. The carrier gas (helium) and the sample gas pass through a dust filter before entering a copper oxide catalyst, where CO is converted to CO2 and elemental hydrogen to H2O.
The resulting CO2 and H2O are then detected in the infrared cells. CO2 and H2O are chemically removed and the nitrogen content is measured in the heat conduction cell.
Optionally, inexpensive argon can be used instead of helium as the carrier gas for determining oxygen and nitrogen.
Mért elemek | hidrogén, nitrogén, oxigén |
Minta típusa | szervetlen |
Kemence iránya | függőleges |
Mintatartó | grafittégelyek |
Alkalmazási terület | automotive, aviation, metal production, metallurgy, quality control, research |
Kemence | elektróda impulzuskemence (max. 8,5 KW*), 3000 °C fölött |
Mérési elv | infrared absorption for oxygen and hydrogen, thermal conductivity for nitrogen |
Tipikus mérési idő | 120 - 180 s |
Szükséges vegyszerek | magnézium-perklorát, nátrium-hidroxid, réz-oxid |
Szükséges gázok | sűrített levegő, hélium 99.995 % tiszta, argon 99.995% tiszta (ha szükséges), mindegyik (2 - 4 bar / 30 - 60 psi) |
Teljesítményigény | 3~ 400 V, 50/60 Hz, max. 8,500 W |
Méretek (szél x mag x mély) | 56 x 78 x 64 cm |
Súly | ~ 165 kg |
Szükséges kiegészítő | PC, monitor, mérleg (0.0001g pontosságú) |
Opcionális kiegészítő | autocleaner, autoloader, external chiller, vivőgáz tisztítás |
- | * 6.8 kW-ra korlátozva az alkalmazásokban |
Műszaki változtatás és tévedés joga fenntartva.